Home | About Talbott's | Manual Systems | Automatic Systems  |  On-Line Request Form

 

 

 

No company is more serious or committed to the environment as Talbott's Ltd.  We've been improving our heaters and boilers constantly over the years to make sure that our equipment surpasses emission regulations throughout Europe and North America.

Our systems burn cleanly and efficiently whether they're burning mdf dust or chipped wood waste.  Each project is different and many states and provinces have their own interpretation of regulations.  We work with you to make sure that your system passes the local codes.

 

 

Emissions standards required by the Canadian/USA environmental authorities are among the toughest in the world; but with Talbott's experience in Europe and unique design this has not been a problem.

 

Talbott's C6 (3.5 Million Btu/Hr) System

Installed In Atlanta GA.

 

Units

Run 1

Run 2

Averages

Test Date

 

06-Dec-00

06-Dec-00

 

Pm

Inches Hg

29.74

29.73

29.74

Ps

Inches Hg

29.36

29.36

29.36

Vm (std)

dscf

35.75

35.03

35.39

Vw (std)

scf

0.47

0.47

0.47

Bws

dimensionless

0.013

0.013

0.013

Md

Ib./Ib.-mole

29.06

29.06

29.06

Ms

Ib./Ib.-mole

28.92

28.92

28.92

Vs

ft./sec

30.20

29.56

29.88

An

ft²

0.001104

0.001104

0.001104

As

ft²

1.40

1.40

1.40

Qa

cfm

2,530

2,476

2,503

Qsd

dscfm

1,593

1,585

1,589

I

percent

94.6

93.2

93.9

P

MMBtu/hr

2.3

2.3

2.3

Cpm

mg/dscm

168.52

160.19

164.36

Cpm

gr/dscf

0.0736

0.0700

0.0718

Epm

Ib./hour

1.01

0.95

0.98

Epm, Allowable

Ib./hour

2.7

2.7

2.7

Epm

Ib / MMBtu

0.4323

0.4109

0.4216

Epm, Allowable

Ib / MMBtu

1.163

1.157

1.1601

% of Allowable

%

37.2%

35.5%

36.3%

KI

Dimensionless

26.08

26.81

26.45

 

Emissions Statement

Talbott's C-Range Systems

Monitoring Organization

Mr Les Hipkiss of Les Hipkiss & Associates - Wombourne, Staffordshire.  Tel: +44 1902 893 452

 

A Chemical Analysis Company.  Duly authorised by the UK Government to independently Monitor Combustion Equipment.

When calculated, all Emission levels are normalised to a level that will provide a fair result, what ever Combustion method a System adopts.

 

All Flue Gas temperature normalized to 273­° Centigrade.

All Oxygen percentage is normalized to 11%.

 

After this calculation was carried out, five various sized Combustion Units ranging from 600kW up to 2,000kW undertook the Emission test.  The Units utilised wet pine shavings to dry MDF Dust & the results are stated in the following table.

 

Average Emission Analysis

 

  Carbon Monoxide    Particulate    Normalised Temperature      Normalised Oxygen

     mg per m³             mg per m³          at the Flue Outlet                  percentage

         85.72                       52                    273° Centigrade                           11%

 

 

The purpose of this statement is to show that the intrinsic design of the Talbott C Range Equipment will perform continuously to a very high standard, meeting “State of the Art” World Emission Requirements. 

 

The high standard of the Talbott C. Range is maintained due to their under-fed pre-heated Automatic Feed System, Ceramic Lined - Triple Pass Combustion Zone & Heat Exchanges with Secondary Ceramic Heat absorption.

 

Further Emissions Data Can Be Found In Our Download Area

 

Emissions  | Case Studies  | Contact Us |Downloads  | Talbott's UK Website  

 

Talbott's Biomass Energy Ltd. - Phone: 011-44- 1785 213366  Fax: 011-44-1785-256418 

Info: sales@talbottsna.com

 

© 2007 Talbott's Heating Ltd.